Skip to content
  • About
    • Spire Integrated Solutions
    • Careers
    • Contact Us
    • News and Events
  • Products
    • Healthcare
      • Sterilization
      • Washing Disinfection
      • Ultrasonic Reprocessing
      • Medical Waste Processing
      • Scrub Sinks
      • Warming Cabinets
      • Morgue & Autopsy
      • Pathology
      • Cleaning Chemistries
    • Life Science
      • Laboratory
        • Sterilization
        • Glassware Washing & Drying
        • Necropsy
        • SS Case Goods
        • Anatomical Pathology
        • Cleaning Chemistries
      • Vivarium/Animal Resources
        • Sterilization
        • Cage Processing
        • Pathology/Necropsy
        • Vacuum Bedding Systems
        • Modular Walls
        • Cleaning Chemistries
      • BioPharma/Medical Device
        • Sterilization
      • BioContainment
        • Sterilization
        • Necropsy/Pathology
        • Equipment Planning/Design Expertise
      • Upgrades & Kits
        • Does your Life Science Sterilizer need an UPGRADE?
      • Infectious Waste Processing
    • COVID-19 Resources
  • Services
    • Service Solutions
    • Installation
    • Preventative Maintenance
    • Equipment Optimization
  • Upgrades
  • Education
    • The inSpire Institute for Healthcare & Life Science Steam Sterilizer Training.
    • Knowledge Database
  • Parts
  • Blog
  • |
  • Contact Us

Safety Features

Blog

What are PRIMUS Steam Sterilizer Steam Pressure Requirements?

September 12, 2023

PRIMUS requires a steam supply pressure of 50 to 80 PSIG to be available to the input of the sterilizer...

Read More
Blog

How to Store and Care for PRIMUS Steam Sterilizer Gaskets

August 23, 2023

General Care of Gaskets Gaskets stored loosely at a normal ambient temperature range should be acceptable to use for 10+...

Read More
Blog

How Does Water Level Detection and Operation Function on PRIMUS Boilers?

August 23, 2023

Overview The Level Control Board and the Low Water Cutoff boards detect water by sensing the current flow between a...

Read More
Blog

What are PRIMUS Steam Sterilizer Bio-Seals?

August 23, 2023

Why Are Bio-Seals Required on Some Steam Sterilizers? Bio-Seals provide a containment barrier between two separate biologically classified areas. BioSeals...

Read More
Blog

How to Troubleshoot Steam Escaping From the Drain on PRIMUS Steam Sterilizers

August 17, 2023

History and Overview A PRIMUS water quench system may be one of three systems. The earliest water quench system consisted...

Read More
Blog

How to Troubleshoot Load Probe Temperature Sensor on PRIMUS Steam Sterilizers

August 17, 2023

Overview A load probe is a temperature sensor located in the sterilizer chamber. During use, the probe is inserted into...

Read More
Blog

How to Measure Regulated Steam Pressure and Adjust Regulator on PRIMUS Steam Sterilizers

August 17, 2023

Benefits of Steam Pressure Regulation The saturated steam tables show that with increased steam temperature comes increased steam pressure. Applying...

Read More
Blog

How to Troubleshoot PRIMUS PSS500 Horizontal Door Control System

August 17, 2023

Overview For safety reasons, the PRIMUS door control system requires the operating technician to press the door button until the...

Read More
Blog

What are the National Electrical Manufacturers Association (NEMA) Enclosure Types for Non-Hazardous Locations?

August 17, 2023

Overview In non-hazardous locations, there are several different NEMA ratings for specific enclosure “types”, their applications, and the environmental conditions...

Read More
Blog

How to Properly Maintain PRIMUS Steam Sterilizers Using Authorized Service Agents (ASA)

August 17, 2023

Authorized Service Agent (ASA) PRIMUS ASA Definition A technician who has attended and satisfactorily completed the PRIMUS Steam Sterilizer School....

Read More

Posts navigation

Older posts

Get Started With Spire

When critical work is underway, equipment reliability and longevity are crucial to keeping operations in motion — that’s why you need Spire at Your Side.

Contact Us
Connect With Us

7936 Forest City Road
Orlando, FL 32810
Phone: (877) 679-7800

  • Contact Us
  • Careers
  • Products

© 2023 Spire Integrated Solutions. All Rights Reserved.

  • Privacy Policy

/ A Chalmers Company

  • About
    • Spire Integrated Solutions
    • Careers
    • Contact Us
    • News and Events
  • Products
    • Healthcare
      • Sterilization
      • Washing Disinfection
      • Ultrasonic Reprocessing
      • Medical Waste Processing
      • Scrub Sinks
      • Warming Cabinets
      • Morgue & Autopsy
      • Pathology
      • Cleaning Chemistries
    • Life Science
      • Laboratory
        • Sterilization
        • Glassware Washing & Drying
        • Necropsy
        • SS Case Goods
        • Anatomical Pathology
        • Cleaning Chemistries
      • Vivarium/Animal Resources
        • Sterilization
        • Cage Processing
        • Pathology/Necropsy
        • Vacuum Bedding Systems
        • Modular Walls
        • Cleaning Chemistries
      • BioPharma/Medical Device
        • Sterilization
      • BioContainment
        • Sterilization
        • Necropsy/Pathology
        • Equipment Planning/Design Expertise
      • Upgrades & Kits
        • Does your Life Science Sterilizer need an UPGRADE?
      • Infectious Waste Processing
    • COVID-19 Resources
  • Services
    • Service Solutions
    • Installation
    • Preventative Maintenance
    • Equipment Optimization
  • Upgrades
  • Education
    • The inSpire Institute for Healthcare & Life Science Steam Sterilizer Training.
    • Knowledge Database
  • Parts
  • Blog
  • |
  • Contact Us

Spire Integrated Solutions COVID-19 Update - Click here